The impact of glazing ratio and window configuration on occupants’ comfort and energy demand: The case study of a school building in Eskisehir, Turkey

Title The impact of glazing ratio and window configuration on occupants’ comfort and energy demand: The case study of a school building in Eskisehir, Turkey
Author Ashrafian Bonab, Touraj, Moazzen, N.
Publication Date: 2019-05
Publication Place - Elsevier
Subject Glazing system, Transparency ratio, Illumination level, Occupant comfort, Energy demand
Type Periodical
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 2210-6707
Record ID f3368808-2ec2-4ce4-9c10-41bf03696eab
Library Location Architecture
Date 2019-05
Sample Text Various investigations have confirmed that pupils and teachers' learning/teaching performance and health depend heavily on the quality and amount of daylight and indoor thermal conditions. The primary aim of using natural light in schools is to reduce energy consumption and costs, but it should also improve students' performance. An appropriate configuration of windows improves visual and thermal comfort by reducing glare, distributing light and controlling solar energy gain. The study focuses on the impact of different transparency ratios (WWR) and window combinations in two critical orientations (west and east) on occupants' comfort and the energy demands of a classroom. A building was selected for a case study investigation at the design stage. One east-facing and one west-facing classroom were studied. The two classrooms were simulated with the aid of the lighting and energy simulation programs DIALux Evo 6.0, DesignBuilder 5.5 and EnergyPlus 8.9. The results indicated that a glazing ratio of 50% would reduce the requirement for artificial lighting by at least 15% as well as providing more comfortable conditions.
DOI 10.1016/j.scs.2019.101483
Cilt 47
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

The impact of glazing ratio and window configuration on occupants’ comfort and energy demand: The case study of a school building in Eskisehir, Turkey

Author Ashrafian Bonab, Touraj, Moazzen, N.
Publication Date 2019-05
Publication Place - Elsevier
Subject Glazing system, Transparency ratio, Illumination level, Occupant comfort, Energy demand
Type Periodical
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 2210-6707
Record ID f3368808-2ec2-4ce4-9c10-41bf03696eab
Library Location Architecture
Date 2019-05
Sample Text Various investigations have confirmed that pupils and teachers' learning/teaching performance and health depend heavily on the quality and amount of daylight and indoor thermal conditions. The primary aim of using natural light in schools is to reduce energy consumption and costs, but it should also improve students' performance. An appropriate configuration of windows improves visual and thermal comfort by reducing glare, distributing light and controlling solar energy gain. The study focuses on the impact of different transparency ratios (WWR) and window combinations in two critical orientations (west and east) on occupants' comfort and the energy demands of a classroom. A building was selected for a case study investigation at the design stage. One east-facing and one west-facing classroom were studied. The two classrooms were simulated with the aid of the lighting and energy simulation programs DIALux Evo 6.0, DesignBuilder 5.5 and EnergyPlus 8.9. The results indicated that a glazing ratio of 50% would reduce the requirement for artificial lighting by at least 15% as well as providing more comfortable conditions.
DOI 10.1016/j.scs.2019.101483
Cilt 47
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait