Evaluation of chemical mechanical polishing-based surface modification on 3D dental implants compared to alternative methods

Title Evaluation of chemical mechanical polishing-based surface modification on 3D dental implants compared to alternative methods
Author Alsaeedi, Riaid, Güler, Zeynep Özdemir
Publication Date: 2018-11-15
Publication Place - MDPI AG
Subject Chemical mechanical polishing, Biocompatibility, Surface structuring
Type Periodical
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 1996-1944
Record ID d369b567-ab58-4635-9c45-f86bfdbb4d8e
Date 2018-11-15
Notes University of Diyala
Sample Text Chemical mechanical polishing (CMP) has been introduced in previous studies as a synergistic technique to modify the surface chemistry and topography of titanium-based implants to control their biocompatibility. In this study, the effectiveness of CMP implementation on titanium-based implant surface modification was compared to machined implants, such as baseline and etching and biphasic calcium phosphate (BCP) particle-based sand blasting treatments, in terms of the surface chemical and mechanical performance. Initially, a lab-scale 3D CMP technique was developed and optimized on commercial dental implant samples. The mechanical competitiveness of the dental implants treated with the selected methods was examined with the Vickers microhardness test as well as pull-out force and removal torque force measurements. Furthermore, the surface structures were quantified through evaluation of the arithmetic mean roughness parameter (Ra). Subsequently, the surface chemistry changes on the treated implants were studied as wettability by contact angle measurement, and surface passivation was evaluated through electrochemical methods. In each evaluation, the CMP treated samples were observed to perform equal or better than the baseline machined implants as well as the current method of choice, the BCP treatment. The ability to control the surface topography and chemistry simultaneously by the use of CMP technique is believed to be the motivation for its adaptation for the modification of implant surfaces in the near future.
DOI 10.3390/ma11112286
Cilt 11
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Evaluation of chemical mechanical polishing-based surface modification on 3D dental implants compared to alternative methods

Author Alsaeedi, Riaid, Güler, Zeynep Özdemir
Publication Date 2018-11-15
Publication Place - MDPI AG
Subject Chemical mechanical polishing, Biocompatibility, Surface structuring
Type Periodical
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 1996-1944
Record ID d369b567-ab58-4635-9c45-f86bfdbb4d8e
Date 2018-11-15
Notes University of Diyala
Sample Text Chemical mechanical polishing (CMP) has been introduced in previous studies as a synergistic technique to modify the surface chemistry and topography of titanium-based implants to control their biocompatibility. In this study, the effectiveness of CMP implementation on titanium-based implant surface modification was compared to machined implants, such as baseline and etching and biphasic calcium phosphate (BCP) particle-based sand blasting treatments, in terms of the surface chemical and mechanical performance. Initially, a lab-scale 3D CMP technique was developed and optimized on commercial dental implant samples. The mechanical competitiveness of the dental implants treated with the selected methods was examined with the Vickers microhardness test as well as pull-out force and removal torque force measurements. Furthermore, the surface structures were quantified through evaluation of the arithmetic mean roughness parameter (Ra). Subsequently, the surface chemistry changes on the treated implants were studied as wettability by contact angle measurement, and surface passivation was evaluated through electrochemical methods. In each evaluation, the CMP treated samples were observed to perform equal or better than the baseline machined implants as well as the current method of choice, the BCP treatment. The ability to control the surface topography and chemistry simultaneously by the use of CMP technique is believed to be the motivation for its adaptation for the modification of implant surfaces in the near future.
DOI 10.3390/ma11112286