Design and fabrication of a robotic tactile device for abdominal palpation

Title Design and fabrication of a robotic tactile device for abdominal palpation
Author Davaria, S., Najafi, F., Mahjoob, M. J., Motahari-Bidgoli, S. M.
Publication Date: 2014
Publication Place - IEEE
Subject Palpation, Abdominal palpation, Tactile device, Tissue stiffness, Cable mechanism
Type Document
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 2-s2.0-84922649895
Record ID 23926479-f201-43ca-887a-ca16eceff162
Date 2014
Notes Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Sample Text Palpation can be used as a manual technique for detecting normal and abnormal tissues. According to the recent applications of the robotic and control systems in medical fields, the design and fabrication of a device capable of abdominal palpation is of great importance. In this paper, a device has been designed and fabricated to be used for palpation examinations. A cable mechanism has been used to meet weight and size criteria of the device. The proposed design has been explained in detail. The device measures contact force between the probe and palpated tissue and also the deflection of the tissue as the probe is pressed against the body. Useful parameters of abdominal tissue such as stiffness can also be obtained.
DOI 10.1109/ICRoM.2014.6990924
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Design and fabrication of a robotic tactile device for abdominal palpation

Author Davaria, S., Najafi, F., Mahjoob, M. J., Motahari-Bidgoli, S. M.
Publication Date 2014
Publication Place - IEEE
Subject Palpation, Abdominal palpation, Tactile device, Tissue stiffness, Cable mechanism
Type Document
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 2-s2.0-84922649895
Record ID 23926479-f201-43ca-887a-ca16eceff162
Date 2014
Notes Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Sample Text Palpation can be used as a manual technique for detecting normal and abnormal tissues. According to the recent applications of the robotic and control systems in medical fields, the design and fabrication of a device capable of abdominal palpation is of great importance. In this paper, a device has been designed and fabricated to be used for palpation examinations. A cable mechanism has been used to meet weight and size criteria of the device. The proposed design has been explained in detail. The device measures contact force between the probe and palpated tissue and also the deflection of the tissue as the probe is pressed against the body. Useful parameters of abdominal tissue such as stiffness can also be obtained.
DOI 10.1109/ICRoM.2014.6990924
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait