Comparison of different actuation concepts for the knee joint during stair-climbing

Title Comparison of different actuation concepts for the knee joint during stair-climbing
Author Unal, Ramazan, Arfaie, Omid
Publication Date: 2024-01-01
Publication Place - IEEE
Type Document
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 979-8-3503-8653-0
Record ID 98520a7b-f2dd-4aa9-8345-dda8da0f0813
Library Location Mechanical Engineering
Date 2024-01-01
Notes TÜBİTAK
Sample Text Maximizing efficiency and minimizing metabolic expenditure are pivotal in advancing transfemoral prosthetics. Designing an energy store/release mechanism emerges as a critical pursuit within this scope. This study mainly compares the performance of the direct drive (DD), series elastic actuator (SEA), and parallel elastic actuator (PEA) concepts for a knee joint during the stair-climbing task. Additionally, the conceptual design of an actuator utilizing a mechanism to transfer the generated force by the actuator to the knee joint is proposed. It is shown that the actuator's weight of the proposed robotic knee (Rnee) prosthesis is 68%, 60%, and 31% lighter than the DD, SEA, and PEA concepts, respectively. Notably, a comprehensive scoring method evaluating mass, complexity, backdrivability, and inertia solidifies the Rnee as a beacon of efficiency. Its overall score surpasses the DD, SEA, and PEA concepts by 162%, 23.5%, and 5%, respectively.
DOI 10.1109/BIOROB60516.2024.10719797
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Comparison of different actuation concepts for the knee joint during stair-climbing

Author Unal, Ramazan, Arfaie, Omid
Publication Date 2024-01-01
Publication Place - IEEE
Type Document
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 979-8-3503-8653-0
Record ID 98520a7b-f2dd-4aa9-8345-dda8da0f0813
Library Location Mechanical Engineering
Date 2024-01-01
Notes TÜBİTAK
Sample Text Maximizing efficiency and minimizing metabolic expenditure are pivotal in advancing transfemoral prosthetics. Designing an energy store/release mechanism emerges as a critical pursuit within this scope. This study mainly compares the performance of the direct drive (DD), series elastic actuator (SEA), and parallel elastic actuator (PEA) concepts for a knee joint during the stair-climbing task. Additionally, the conceptual design of an actuator utilizing a mechanism to transfer the generated force by the actuator to the knee joint is proposed. It is shown that the actuator's weight of the proposed robotic knee (Rnee) prosthesis is 68%, 60%, and 31% lighter than the DD, SEA, and PEA concepts, respectively. Notably, a comprehensive scoring method evaluating mass, complexity, backdrivability, and inertia solidifies the Rnee as a beacon of efficiency. Its overall score surpasses the DD, SEA, and PEA concepts by 162%, 23.5%, and 5%, respectively.
DOI 10.1109/BIOROB60516.2024.10719797
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...