Design and fabrication of a robotic tactile device for abdominal palpation

İsim Design and fabrication of a robotic tactile device for abdominal palpation
Yazar Davaria, S., Najafi, F., Mahjoob, M. J., Motahari-Bidgoli, S. M.
Basım Tarihi: 2014
Basım Yeri - IEEE
Konu Palpation, Abdominal palpation, Tactile device, Tissue stiffness, Cable mechanism
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 2-s2.0-84922649895
Kayıt Numarası 23926479-f201-43ca-887a-ca16eceff162
Tarih 2014
Notlar Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Örnek Metin Palpation can be used as a manual technique for detecting normal and abnormal tissues. According to the recent applications of the robotic and control systems in medical fields, the design and fabrication of a device capable of abdominal palpation is of great importance. In this paper, a device has been designed and fabricated to be used for palpation examinations. A cable mechanism has been used to meet weight and size criteria of the device. The proposed design has been explained in detail. The device measures contact force between the probe and palpated tissue and also the deflection of the tissue as the probe is pressed against the body. Useful parameters of abdominal tissue such as stiffness can also be obtained.
DOI 10.1109/ICRoM.2014.6990924
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Design and fabrication of a robotic tactile device for abdominal palpation

Yazar Davaria, S., Najafi, F., Mahjoob, M. J., Motahari-Bidgoli, S. M.
Basım Tarihi 2014
Basım Yeri - IEEE
Konu Palpation, Abdominal palpation, Tactile device, Tissue stiffness, Cable mechanism
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 2-s2.0-84922649895
Kayıt Numarası 23926479-f201-43ca-887a-ca16eceff162
Tarih 2014
Notlar Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Örnek Metin Palpation can be used as a manual technique for detecting normal and abnormal tissues. According to the recent applications of the robotic and control systems in medical fields, the design and fabrication of a device capable of abdominal palpation is of great importance. In this paper, a device has been designed and fabricated to be used for palpation examinations. A cable mechanism has been used to meet weight and size criteria of the device. The proposed design has been explained in detail. The device measures contact force between the probe and palpated tissue and also the deflection of the tissue as the probe is pressed against the body. Useful parameters of abdominal tissue such as stiffness can also be obtained.
DOI 10.1109/ICRoM.2014.6990924
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.