Evaluation of NaOH pre-treatment on the corrosion behavior and surface characteristics of hydroxyapatite coated NiTi alloy

Title Evaluation of NaOH pre-treatment on the corrosion behavior and surface characteristics of hydroxyapatite coated NiTi alloy
Author Şimşek, Görkem Muttalip, Ipekoglu, M., Yapıcı, Güney Güven
Publication Date: 2020-08-02
Publication Place - Springer Nature
Subject NiTi, Coating, Hydroxyapatite, Corrosion, Cell viability, Surface wettability
Type Periodical
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 0947-8396
Record ID d6c3ab6e-56a3-4803-9d7d-77aca109e532
Library Location Mechanical Engineering
Date 2020-08-02
Notes Ozyegin University
Sample Text Successful short-term implementation of nickel-titanium (NiTi) alloys as implants has been a motivation for the development of long-term applications. However, rendering these as safe implant materials is challenging. The major problem associated with the use of NiTi for in-vivo applications is the potential risk of Ni release from the implant surface due to the corrosive environment of the body. Various methods including surface treatment techniques with acid and alkali solutions and application of biocompatible coatings have been used to overcome these difficulties. In particular, NaOH pre-treatment has been commonly performed for surface activation of the substrate material to enhance the adhesion properties of coatings. The present work investigates the effect of NaOH pre-treatment on the hydroxyapatite (HA) coating and the resulting corrosion behavior of and cell response to HA coated NiTi wires. Microstructural examinations showed that the coating integrity deteriorated with prior NaOH treatment which also increased the corrosion rate as evidenced by potentiodynamic measurements. XPS analysis revealed heightened Ni levels on the sample surfaces and cytotoxicity tests showed decreased cell viability for the samples with pre-treatment. Absence of NaOH pre-treatment led to lower contact angle values pointing to higher biocompatibility.
DOI 10.1007/s00339-020-03847-1
Cilt 126
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Evaluation of NaOH pre-treatment on the corrosion behavior and surface characteristics of hydroxyapatite coated NiTi alloy

Author Şimşek, Görkem Muttalip, Ipekoglu, M., Yapıcı, Güney Güven
Publication Date 2020-08-02
Publication Place - Springer Nature
Subject NiTi, Coating, Hydroxyapatite, Corrosion, Cell viability, Surface wettability
Type Periodical
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 0947-8396
Record ID d6c3ab6e-56a3-4803-9d7d-77aca109e532
Library Location Mechanical Engineering
Date 2020-08-02
Notes Ozyegin University
Sample Text Successful short-term implementation of nickel-titanium (NiTi) alloys as implants has been a motivation for the development of long-term applications. However, rendering these as safe implant materials is challenging. The major problem associated with the use of NiTi for in-vivo applications is the potential risk of Ni release from the implant surface due to the corrosive environment of the body. Various methods including surface treatment techniques with acid and alkali solutions and application of biocompatible coatings have been used to overcome these difficulties. In particular, NaOH pre-treatment has been commonly performed for surface activation of the substrate material to enhance the adhesion properties of coatings. The present work investigates the effect of NaOH pre-treatment on the hydroxyapatite (HA) coating and the resulting corrosion behavior of and cell response to HA coated NiTi wires. Microstructural examinations showed that the coating integrity deteriorated with prior NaOH treatment which also increased the corrosion rate as evidenced by potentiodynamic measurements. XPS analysis revealed heightened Ni levels on the sample surfaces and cytotoxicity tests showed decreased cell viability for the samples with pre-treatment. Absence of NaOH pre-treatment led to lower contact angle values pointing to higher biocompatibility.
DOI 10.1007/s00339-020-03847-1
Cilt 126
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait