Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge

Title Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge
Author Yaraş, Y. S., Gündüz, A. B., Sağlam, G., Ölçer, S., Civitçi, F., Baris, İ., Yaralıoğlu, Göksen Göksenin, Urey, H.
Publication Date: 2017-11
Publication Place - SPIE
Subject Fiber optic sensor, Blood coagulation, Activated partial thromboplastin time, Point-of-care, Lab-on-a-chip
Type Periodical
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 1083-3668
Record ID f85f5efa-0f63-4c9c-9c20-5d665ae4d55c
Library Location Electrical & Electronics Engineering
Date 2017-11
Sample Text In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer’s datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements.
DOI 10.1117/1.JBO.22.11.117001
Cilt 22
View in source Özyeğin University Özyeğin University - Ottoman library catalog search
Özyeğin University - Ottoman library catalog search Özyeğin University

Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge

Author Yaraş, Y. S., Gündüz, A. B., Sağlam, G., Ölçer, S., Civitçi, F., Baris, İ., Yaralıoğlu, Göksen Göksenin, Urey, H.
Publication Date 2017-11
Publication Place - SPIE
Subject Fiber optic sensor, Blood coagulation, Activated partial thromboplastin time, Point-of-care, Lab-on-a-chip
Type Periodical
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 1083-3668
Record ID f85f5efa-0f63-4c9c-9c20-5d665ae4d55c
Library Location Electrical & Electronics Engineering
Date 2017-11
Sample Text In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer’s datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements.
DOI 10.1117/1.JBO.22.11.117001
Cilt 22
Özyeğin University - Ottoman library catalog search
Özyeğin University You are being redirected...

Please wait