Experimental and numerical investigation of ground heat exchangers in the building foundation

Title Experimental and numerical investigation of ground heat exchangers in the building foundation
Author Kayaci, N., Demir, H., Kanbur, B. B., Atayilmaz, S. O., Agra, O., Acet, Ruşen Can, Gemici, Z.
Publication Date: 2019-05-15
Publication Place - Elsevier
Subject Ground source heat pump, Computational modeling, Horizontal heat exchanger, Transient analysis, Building energy simulations
Type Periodical
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 0196-8904
Record ID 55d8b422-af46-44d4-9faf-7f2a625793f4
Date 2019-05-15
Notes Ministry of Science, Industry, and Technology of Turkey under SAN-TEZ program ; Mir Unique Solutions (company)
Sample Text The current study proposes a novel method with the experimental and numerical studies for the ground source heat pumps, which are known as environment-friendly and efficient heating & cooling systems to overcome their economic drawbacks in the applied engineering operations. The experimental studies are carried out in the newly built Central Laboratory of Yildiz Technical University, Davutpasa Campus, Istanbul, Turkey. The long parallel heat exchanger pipes are placed in two different layers of the ground that are (1) under the building foundation (ground layer), and (2) in the building foundation (concrete layer), respectively. Besides, a unique numerical model is developed in MATLAB environment to obtain temperature distributions in ground and concrete layers. Then, the numerical outputs are validated with the observed experimental results. The daily average of the energy amount extracted from the Ground and Concrete Loops was found as 5.51 and 4.63 kWh/day, respectively. The results are found satisfying for real applications in the building foundations.
DOI 10.1016/j.enconman.2019.03.032
Cilt 188
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Experimental and numerical investigation of ground heat exchangers in the building foundation

Author Kayaci, N., Demir, H., Kanbur, B. B., Atayilmaz, S. O., Agra, O., Acet, Ruşen Can, Gemici, Z.
Publication Date 2019-05-15
Publication Place - Elsevier
Subject Ground source heat pump, Computational modeling, Horizontal heat exchanger, Transient analysis, Building energy simulations
Type Periodical
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 0196-8904
Record ID 55d8b422-af46-44d4-9faf-7f2a625793f4
Date 2019-05-15
Notes Ministry of Science, Industry, and Technology of Turkey under SAN-TEZ program ; Mir Unique Solutions (company)
Sample Text The current study proposes a novel method with the experimental and numerical studies for the ground source heat pumps, which are known as environment-friendly and efficient heating & cooling systems to overcome their economic drawbacks in the applied engineering operations. The experimental studies are carried out in the newly built Central Laboratory of Yildiz Technical University, Davutpasa Campus, Istanbul, Turkey. The long parallel heat exchanger pipes are placed in two different layers of the ground that are (1) under the building foundation (ground layer), and (2) in the building foundation (concrete layer), respectively. Besides, a unique numerical model is developed in MATLAB environment to obtain temperature distributions in ground and concrete layers. Then, the numerical outputs are validated with the observed experimental results. The daily average of the energy amount extracted from the Ground and Concrete Loops was found as 5.51 and 4.63 kWh/day, respectively. The results are found satisfying for real applications in the building foundations.
DOI 10.1016/j.enconman.2019.03.032
Cilt 188
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait