A double-needle gold-silver electrodes continuous glucose monitoring device

Title A double-needle gold-silver electrodes continuous glucose monitoring device
Author Hassine, Chedia Ben Ali, Tekin, A.
Publication Date: 2023-06
Publication Place - Elsevier
Subject Continuous glucose monitoring (CGM), Ferrocene, Glucose oxidase, Two needles
Type Periodical
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 1959-0318
Record ID 53015e9d-12dd-414d-8c59-6fa38c9b9a8a
Date 2023-06
Sample Text Objectives: Diabetes is a serious, long-term disease and the use of continuous glucose monitoring sensors can reduce reliance on other painful invasive blood testing methods such as the finger blood glucose test. According to our work, a low-cost continuous glucose sensor has been developed based on electrochemical measurement techniques. Materials: The sensor is based on a two needles system; a gold and a silver electrode are integrated into a circular shaped electronic printed circuit board (PCB). The sensing part is based on biological electrochemical measurements. Glucose oxidase (Gox) was used as the active sensing element and ferrocene (Fc) as a mediator. Simple and low-cost coating methods were used; these methods are self-assembled monolayers and deep coating. This will reduce the final cost of the sensor as no expensive technique was used. The electrical subsystem contains a low-noise and low-power trans-impedance front-end as well as a single-chip low-power Bluetooth microcontroller with a 12-bit Analog-to-Digital Converter (ADC). Results: The sensor was tested in various concentrations of glucose. As a result of initial in vitro experiments, detailed analytical performance metrics are presented. The device has consistently shown a sensitivity of 3.059 mV/(mg/dl) reading with a linear range of 0-400 mg/dl. Conclusion: The proposed study shows promising results for glucose detection. Thus, this type of sensor can be used for different analyzes targeting biological applications after further investigations and analysis.
DOI 10.1016/j.irbm.2023.100752
Cilt 44
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

A double-needle gold-silver electrodes continuous glucose monitoring device

Author Hassine, Chedia Ben Ali, Tekin, A.
Publication Date 2023-06
Publication Place - Elsevier
Subject Continuous glucose monitoring (CGM), Ferrocene, Glucose oxidase, Two needles
Type Periodical
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 1959-0318
Record ID 53015e9d-12dd-414d-8c59-6fa38c9b9a8a
Date 2023-06
Sample Text Objectives: Diabetes is a serious, long-term disease and the use of continuous glucose monitoring sensors can reduce reliance on other painful invasive blood testing methods such as the finger blood glucose test. According to our work, a low-cost continuous glucose sensor has been developed based on electrochemical measurement techniques. Materials: The sensor is based on a two needles system; a gold and a silver electrode are integrated into a circular shaped electronic printed circuit board (PCB). The sensing part is based on biological electrochemical measurements. Glucose oxidase (Gox) was used as the active sensing element and ferrocene (Fc) as a mediator. Simple and low-cost coating methods were used; these methods are self-assembled monolayers and deep coating. This will reduce the final cost of the sensor as no expensive technique was used. The electrical subsystem contains a low-noise and low-power trans-impedance front-end as well as a single-chip low-power Bluetooth microcontroller with a 12-bit Analog-to-Digital Converter (ADC). Results: The sensor was tested in various concentrations of glucose. As a result of initial in vitro experiments, detailed analytical performance metrics are presented. The device has consistently shown a sensitivity of 3.059 mV/(mg/dl) reading with a linear range of 0-400 mg/dl. Conclusion: The proposed study shows promising results for glucose detection. Thus, this type of sensor can be used for different analyzes targeting biological applications after further investigations and analysis.
DOI 10.1016/j.irbm.2023.100752
Cilt 44
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait