Author
Sajadifar, Seyed Vahid, Yapıcı, Güney Güven
Publication Date
2014-01
Publication Place
-
Elsevier
Subject
Titanium, Equal channel angular extrusion/pressing, Severe plastic deformation, Modeling of hot deformation
Type
Periodical
Language
English
Digital
Yes
Manuscript
No
Library
Özyeğin University
Library Asset ID
0261-3069
Record ID
d8831c0d-4ee5-4e44-9add-b6e4c1299a9c
Library Location
Mechanical Engineering
Date
2014-01
Notes
Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Sample Text
In the present study, compression tests were performed at temperatures of 600–900 °C and at strain rates of 0.001–0.1 s−1 to study the deformation and workability characteristics of commercially pure titanium after severe plastic deformation (SPD). It was found that the effects of temperature and strain rate are significant in dictating the steady state flow stress levels and the strain values corresponding to peak flow stress. The strain rate sensitivity (m) during hot compression of severely deformed Ti was shown to be strongly temperature dependent, where m increased with the increase in deformation temperature up to 800 °C. High temperature workability was analyzed based on the flow localization parameter (FLP). According to the FLP values, deformation at and below 700 °C is prone to flow localization. The flow behavior was predicted using Arrhenius type and dislocation density based models. The validities of the models were demonstrated with reasonable agreement in comparison to the experimental stress–strain responses.
DOI
10.1016/j.matdes.2013.07.057
Cilt
53