Evaluation of code provisions for seismic performance of unachored liquid storage tanks

Title Evaluation of code provisions for seismic performance of unachored liquid storage tanks
Author Erkmen, Bülent
Publication Date: 2017
Subject Base uplift, Liquid storage tanks, Seismic performance, Unanchored tanks
Type Document
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 2-s2.0-85042504180
Record ID 18a4462d-5d5f-47a1-b399-be41465572d7
Library Location Civil Engineering
Date 2017
Sample Text Seismic performance of two unanchored liquid-storage tanks with tank diameter of 24.5 m and 36 m and operating liquid height of 12.2 m and 20.0 m, respectively were investigated using Coupled Eulerian-Lagrangian (CEL) and mechanical spring-mass analogy nonlinear finite element computational methods. The CEL approach includes the effects of higher modes of liquid vibration (sloshing), liquid breaking effects, and liquid-structure interaction during seismic loading. The modern seismic design provisions for liquid-storage tanks, on the other hand, are based on a mechanical spring-mass analogy. This approach neglects the higher vibration modes for the sloshing water, liquid-structure interaction, and effects of tank base uplift on seismic performance. For the tanks, base uplift histories were computed with both modeling approaches through nonlinear time history analysis performed using five recorded earthquake acceleration data. The uplift histories were compared to evaluate the adequacy of code seismic design provisions for unanchored tanks, and to determine whether the mechanical spring-mass analogy can be used to predict seismic performance of unanchored tanks. Analysis results show that the traditional mechanical spring-mass analogy, which is the basis for the current seismic design provisions, does not capture tank uplift history and its effects on dynamic loads. This approach underpredicts the total numbers of tank uplifts during seismic loading. The maximum tank base uplift computed using mechanical spring-mass analogy had an average error between 22% and 58 % for each tank. The results show that there is a need to developed a modify version of the traditional mechanical spring-mass analogy to be used for predicting seismic performance of unanchored liquid-storage tanks.
DOI 10.7712/120117.5523.18579
Cilt 1
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Evaluation of code provisions for seismic performance of unachored liquid storage tanks

Author Erkmen, Bülent
Publication Date 2017
Subject Base uplift, Liquid storage tanks, Seismic performance, Unanchored tanks
Type Document
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 2-s2.0-85042504180
Record ID 18a4462d-5d5f-47a1-b399-be41465572d7
Library Location Civil Engineering
Date 2017
Sample Text Seismic performance of two unanchored liquid-storage tanks with tank diameter of 24.5 m and 36 m and operating liquid height of 12.2 m and 20.0 m, respectively were investigated using Coupled Eulerian-Lagrangian (CEL) and mechanical spring-mass analogy nonlinear finite element computational methods. The CEL approach includes the effects of higher modes of liquid vibration (sloshing), liquid breaking effects, and liquid-structure interaction during seismic loading. The modern seismic design provisions for liquid-storage tanks, on the other hand, are based on a mechanical spring-mass analogy. This approach neglects the higher vibration modes for the sloshing water, liquid-structure interaction, and effects of tank base uplift on seismic performance. For the tanks, base uplift histories were computed with both modeling approaches through nonlinear time history analysis performed using five recorded earthquake acceleration data. The uplift histories were compared to evaluate the adequacy of code seismic design provisions for unanchored tanks, and to determine whether the mechanical spring-mass analogy can be used to predict seismic performance of unanchored tanks. Analysis results show that the traditional mechanical spring-mass analogy, which is the basis for the current seismic design provisions, does not capture tank uplift history and its effects on dynamic loads. This approach underpredicts the total numbers of tank uplifts during seismic loading. The maximum tank base uplift computed using mechanical spring-mass analogy had an average error between 22% and 58 % for each tank. The results show that there is a need to developed a modify version of the traditional mechanical spring-mass analogy to be used for predicting seismic performance of unanchored liquid-storage tanks.
DOI 10.7712/120117.5523.18579
Cilt 1
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait