Blood clotting time measurement using a miniaturized high-frequency ultrasound sensor

Title Blood clotting time measurement using a miniaturized high-frequency ultrasound sensor
Author Sobhani, M. R., Majidi, Negar, Yaralıoğlu, Göksen Göksenin
Publication Date: 2023
Publication Place - IEEE
Subject Component, Formatting, Insert, Style, Styling
Type Document
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 979-835034645-9
Record ID bd068fec-7c5f-4d1c-869e-e959f10cbbbf
Library Location Electrical & Electronics Engineering
Date 2023
Sample Text This paper demonstrates a novel blood coagulation time measurement methodology that requires as low as 1 microliter of whole blood. The blood sample is placed on the top surface of a fused quartz plate where an ultrasonic transducer is fabricated on the bottom surface. The location of the blood sample is aligned with the transducer; therefore, the reflected acoustic waves from the blood/quartz interface are captured and converted to electrical signals by the transducer. The transducer is made of an 8 μm thick zinc oxide (ZnO) thin film that operates at 400 MHz. The acoustic impedance of blood changes due to the coagulation process. This affects the reflection coefficient and amplitude of the reflected waves from the blood/quartz interface. Thus, the blood coagulation time is determined by monitoring the amplitude of reflected acoustic waves. In the experiments, whole blood was used without any sample preparation. The method was tested using citrated blood with calcium chloride and activated partial thromboplastin (aPTT) reagents. We observed that aPTT coagulation times lengthened from 25 sec. to 47 sec. with the addition of heparin. The proposed method has the potential to be used in a disposable low-cost portable coagulation time measurement cartridge for patient self-testing.
DOI 10.1109/IUS51837.2023.10307897
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Blood clotting time measurement using a miniaturized high-frequency ultrasound sensor

Author Sobhani, M. R., Majidi, Negar, Yaralıoğlu, Göksen Göksenin
Publication Date 2023
Publication Place - IEEE
Subject Component, Formatting, Insert, Style, Styling
Type Document
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 979-835034645-9
Record ID bd068fec-7c5f-4d1c-869e-e959f10cbbbf
Library Location Electrical & Electronics Engineering
Date 2023
Sample Text This paper demonstrates a novel blood coagulation time measurement methodology that requires as low as 1 microliter of whole blood. The blood sample is placed on the top surface of a fused quartz plate where an ultrasonic transducer is fabricated on the bottom surface. The location of the blood sample is aligned with the transducer; therefore, the reflected acoustic waves from the blood/quartz interface are captured and converted to electrical signals by the transducer. The transducer is made of an 8 μm thick zinc oxide (ZnO) thin film that operates at 400 MHz. The acoustic impedance of blood changes due to the coagulation process. This affects the reflection coefficient and amplitude of the reflected waves from the blood/quartz interface. Thus, the blood coagulation time is determined by monitoring the amplitude of reflected acoustic waves. In the experiments, whole blood was used without any sample preparation. The method was tested using citrated blood with calcium chloride and activated partial thromboplastin (aPTT) reagents. We observed that aPTT coagulation times lengthened from 25 sec. to 47 sec. with the addition of heparin. The proposed method has the potential to be used in a disposable low-cost portable coagulation time measurement cartridge for patient self-testing.
DOI 10.1109/IUS51837.2023.10307897
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait