Rethinking temporal demand data to reduce distribution transformer losses: A case study from a Turkish DSO

Title Rethinking temporal demand data to reduce distribution transformer losses: A case study from a Turkish DSO
Author Sancar, Semanur, Kartci, Emin, Poyrazoğlu, Göktürk
Publication Date: 2021
Publication Place - IEEE
Subject Data-driven grid planning, Efficiency, Investment, Losses, Optimization, Transformers
Type Document
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Library Asset ID 978-166543512-3
Record ID 494f7091-1b38-406c-bbdb-51d7e87d44dc
Library Location Electrical & Electronics Engineering
Date 2021
Sample Text With the increase in digital measurement and monitoring devices in the Turkish electricity grid, the possibilities of processing the obtained data and revealing meaningful information are also increasing. In this project, an optimization study is carried out on optimal sizing of transformers by using sub-hourly historical load data collected from transformers. In the study on transformer efficiency based on the regulations renewed in the last 10 years in Turkey, the core and copper losses of the transformers are estimated based on historical data, and the efficiency increase that would be provided in case of renewal of the transformers is calculated. According to the results obtained, it is predicted that transformer losses can be reduced by 50% and annual savings of approximately 1 kWh can be achieved for each dollar invested.
DOI 10.1109/GPECOM52585.2021.9587563
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Rethinking temporal demand data to reduce distribution transformer losses: A case study from a Turkish DSO

Author Sancar, Semanur, Kartci, Emin, Poyrazoğlu, Göktürk
Publication Date 2021
Publication Place - IEEE
Subject Data-driven grid planning, Efficiency, Investment, Losses, Optimization, Transformers
Type Document
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Library Asset ID 978-166543512-3
Record ID 494f7091-1b38-406c-bbdb-51d7e87d44dc
Library Location Electrical & Electronics Engineering
Date 2021
Sample Text With the increase in digital measurement and monitoring devices in the Turkish electricity grid, the possibilities of processing the obtained data and revealing meaningful information are also increasing. In this project, an optimization study is carried out on optimal sizing of transformers by using sub-hourly historical load data collected from transformers. In the study on transformer efficiency based on the regulations renewed in the last 10 years in Turkey, the core and copper losses of the transformers are estimated based on historical data, and the efficiency increase that would be provided in case of renewal of the transformers is calculated. According to the results obtained, it is predicted that transformer losses can be reduced by 50% and annual savings of approximately 1 kWh can be achieved for each dollar invested.
DOI 10.1109/GPECOM52585.2021.9587563
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait