Numerical and theoretical analysis of external gear pump

Title Numerical and theoretical analysis of external gear pump
Author İmamoğlu, Deniz
Publication Date: 2019-01-28
Type Document
Language English
Digital Yes
Manuscript No
Library: Özyeğin University
Record ID b03dbc2a-31b9-48e3-b6fb-198b75c9d324
Library Location Department of Mechanical Engineering
Date 2019-01-28
Sample Text External gear pumps are one of the mostly used pump types in the uid power applications due to simplicity, low cost and long operation period. However, there are some disadvantages such as internal leakages, noise and vibration with gear pumps. This study investigates comparison of theoretical calculations and 2D-3D numerical simulations with considering temperature e ects on tip leakage. 2D numerical simulations have been done for pressure di erence from 2 bars up to 10 bars for seven di erent rotational speeds. Additionally, the e ect of wall temperature varied from 303 K up to 333 K has been investigated on the performance of gear pump. 3D numerical simulations could be performed only for 2 cases due to long computational time. Because of extra assumptions made in theoretical calculations for tip leakages, it is shown that there are some deviations between theoretical and numerical results. These deviations are due to pressure drop which occurs because of energy dissipation between two teeth tips which can be observed in numerical simulations and fully developed ow assumption made in theoretical analysis. Results of numerical study show that the fully developed assumption in the gap between gear tooth and wall is not appropriate. In addition, face leakage and gearing zone leakage has been investigated in 3D numerical simulations to compare with theoretical calculations. Furthermore, it has been shown that leakages increase linearly with temperature rise at the wall due to the drop in the viscosity of the liquid.
View in source Özyeğin University Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University - Historical works, archives, and periodicals search engine Özyeğin University

Numerical and theoretical analysis of external gear pump

Author İmamoğlu, Deniz
Publication Date 2019-01-28
Type Document
Language English
Digital Yes
Manuscript No
Library Özyeğin University
Record ID b03dbc2a-31b9-48e3-b6fb-198b75c9d324
Library Location Department of Mechanical Engineering
Date 2019-01-28
Sample Text External gear pumps are one of the mostly used pump types in the uid power applications due to simplicity, low cost and long operation period. However, there are some disadvantages such as internal leakages, noise and vibration with gear pumps. This study investigates comparison of theoretical calculations and 2D-3D numerical simulations with considering temperature e ects on tip leakage. 2D numerical simulations have been done for pressure di erence from 2 bars up to 10 bars for seven di erent rotational speeds. Additionally, the e ect of wall temperature varied from 303 K up to 333 K has been investigated on the performance of gear pump. 3D numerical simulations could be performed only for 2 cases due to long computational time. Because of extra assumptions made in theoretical calculations for tip leakages, it is shown that there are some deviations between theoretical and numerical results. These deviations are due to pressure drop which occurs because of energy dissipation between two teeth tips which can be observed in numerical simulations and fully developed ow assumption made in theoretical analysis. Results of numerical study show that the fully developed assumption in the gap between gear tooth and wall is not appropriate. In addition, face leakage and gearing zone leakage has been investigated in 3D numerical simulations to compare with theoretical calculations. Furthermore, it has been shown that leakages increase linearly with temperature rise at the wall due to the drop in the viscosity of the liquid.
Özyeğin University - Historical works, archives, and periodicals search engine
Özyeğin University You are being redirected...

Please wait