DC-link capacitor lifetime under various operating conditions | Kütüphane.osmanlica.com

DC-link capacitor lifetime under various operating conditions

İsim DC-link capacitor lifetime under various operating conditions
Yazar Bilgin, Mert Serdar, Poyrazoğlu, Göktürk, Aktem, M., Er, E.
Basım Tarihi: 2019
Basım Yeri - IEEE
Konu Capacitor, Lifetime, Converter, DC-Link capacitor, DC/AC converter
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 978-1-7281-3202-0
Kayıt Numarası 033697e7-0714-4bf0-a86e-6fa05e605bf3
Lokasyon Electrical & Electronics Engineering
Tarih 2019
Örnek Metin A grid-tied DC/AC converter transfers the energy to the power system under different operating conditions such as DC-Link voltage level, power factor, and instability in the grid voltage. There are some effects of the operating conditions to the DC-Link capacitor lifetime. The DC-Link capacitor current characteristic is affected by the operating conditions. In this paper, the DC-Link capacitor lifetime and current ripple are observed under different DC-Link voltage level, power factor and grid conditions for grid-tied 10kVA DC/AC converter. Simulation results are shown and interpreted.
DOI 10.1109/CPE.2019.8862317
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

DC-link capacitor lifetime under various operating conditions

Yazar Bilgin, Mert Serdar, Poyrazoğlu, Göktürk, Aktem, M., Er, E.
Basım Tarihi 2019
Basım Yeri - IEEE
Konu Capacitor, Lifetime, Converter, DC-Link capacitor, DC/AC converter
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 978-1-7281-3202-0
Kayıt Numarası 033697e7-0714-4bf0-a86e-6fa05e605bf3
Lokasyon Electrical & Electronics Engineering
Tarih 2019
Örnek Metin A grid-tied DC/AC converter transfers the energy to the power system under different operating conditions such as DC-Link voltage level, power factor, and instability in the grid voltage. There are some effects of the operating conditions to the DC-Link capacitor lifetime. The DC-Link capacitor current characteristic is affected by the operating conditions. In this paper, the DC-Link capacitor lifetime and current ripple are observed under different DC-Link voltage level, power factor and grid conditions for grid-tied 10kVA DC/AC converter. Simulation results are shown and interpreted.
DOI 10.1109/CPE.2019.8862317
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.