Total harmonic distortion and power factor improvement technique for CRM flyback PFC converters

İsim Total harmonic distortion and power factor improvement technique for CRM flyback PFC converters
Yazar Kavcı, Mustafa, Tekin, Ahmet, Tarhan, C.
Basım Tarihi: 2019
Basım Yeri - IEEE
Konu Power factor correction, Total harmonic distortion, Critical conduction mode flyback converter
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 978-1-7281-2788-0
Kayıt Numarası 13740b17-5f6f-4a58-888d-8e029b119499
Lokasyon Electrical & Electronics Engineering
Tarih 2019
Örnek Metin In many of today's solid-state lighting applications, Critical Conduction Mode (CCM) Flyback PFC converter is a popular solution due to its limited component count and simple structure with respect to other SMPS topologies. As described in international standards documents (IEC/EN 61000-3-2), drivers are required to demonstrate a power factor results greater than 0.9 and lower THD for power levels above 25W. Due to non-sinusoidal input current waveform of the traditional constant-on-time control method, achieving improved PF and THD is quite difficult. In this paper, a new control method is introduced in an effort to improve power factor and total harmonic distortion of Voltage Mode CRM Flyback PFC Converter. The work proposes injection of a compensating sin(ωt) signal component in the feedback path utilizing an additional primary transformer winding to linearize the current from the source. The detailed theoretical analysis is presented along with measurement results of a 30W high-power system prototype.
DOI 10.1109/MWSCAS.2019.8885187
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Total harmonic distortion and power factor improvement technique for CRM flyback PFC converters

Yazar Kavcı, Mustafa, Tekin, Ahmet, Tarhan, C.
Basım Tarihi 2019
Basım Yeri - IEEE
Konu Power factor correction, Total harmonic distortion, Critical conduction mode flyback converter
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 978-1-7281-2788-0
Kayıt Numarası 13740b17-5f6f-4a58-888d-8e029b119499
Lokasyon Electrical & Electronics Engineering
Tarih 2019
Örnek Metin In many of today's solid-state lighting applications, Critical Conduction Mode (CCM) Flyback PFC converter is a popular solution due to its limited component count and simple structure with respect to other SMPS topologies. As described in international standards documents (IEC/EN 61000-3-2), drivers are required to demonstrate a power factor results greater than 0.9 and lower THD for power levels above 25W. Due to non-sinusoidal input current waveform of the traditional constant-on-time control method, achieving improved PF and THD is quite difficult. In this paper, a new control method is introduced in an effort to improve power factor and total harmonic distortion of Voltage Mode CRM Flyback PFC Converter. The work proposes injection of a compensating sin(ωt) signal component in the feedback path utilizing an additional primary transformer winding to linearize the current from the source. The detailed theoretical analysis is presented along with measurement results of a 30W high-power system prototype.
DOI 10.1109/MWSCAS.2019.8885187
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.