Preconcentration and Electroanalysis of Copper at Glassy Carbon Electrode Modified with Poly(2-aminothiazole) | Kütüphane.osmanlica.com

Preconcentration and Electroanalysis of Copper at Glassy Carbon Electrode Modified with Poly(2-aminothiazole)

İsim Preconcentration and Electroanalysis of Copper at Glassy Carbon Electrode Modified with Poly(2-aminothiazole)
Yazar Ciftci, H, Testereci, H N, Oektem, Z
Konu Acetonitrile, Copper, Electrodes, Electrolytes, Eyeglasses
Tür Süreli Yayın
Dil Arapça
Dijital Hayır
Yazma Hayır
Kütüphane: Purdue Üniversitesi Kütüphaneleri
Demirbaş Numarası ISSN: 1303-9709
Kayıt Numarası cdi_proquest_miscellaneous_869826512
Notlar Conducting poly(2-aminothiazole), PAT, was synthesized in acetonitrile with tetrabutylammonium tetrafluoroborate, TBAFB, as supporting electrolyte via constant potential electrolysis, CPE. Glassy carbon, GC, electrode was modified by immersing the electrode in a DMSO solution of PAT. Preconcentration of copper on polymer matrix was carried out at -0.7 V. The effects of preconcentration time and pH and Cu(II) concentration of the preconcentration solution on the stripping peak current of copper were studied.
Atıf Kaynağı Copper Technical Reference Library
Bir Parçası Olduğu Gazi University Journal of Science, 1901-01, Vol.24 (1), p.11-16
Kaynağa git Purdue Üniversitesi Kütüphaneleri Purdue University Libraries
Purdue University Libraries Purdue Üniversitesi Kütüphaneleri
Kaynağa git

Preconcentration and Electroanalysis of Copper at Glassy Carbon Electrode Modified with Poly(2-aminothiazole)

Yazar Ciftci, H, Testereci, H N, Oektem, Z
Konu Acetonitrile, Copper, Electrodes, Electrolytes, Eyeglasses
Tür Süreli Yayın
Dil Arapça
Dijital Hayır
Yazma Hayır
Kütüphane Purdue Üniversitesi Kütüphaneleri
Demirbaş Numarası ISSN: 1303-9709
Kayıt Numarası cdi_proquest_miscellaneous_869826512
Notlar Conducting poly(2-aminothiazole), PAT, was synthesized in acetonitrile with tetrabutylammonium tetrafluoroborate, TBAFB, as supporting electrolyte via constant potential electrolysis, CPE. Glassy carbon, GC, electrode was modified by immersing the electrode in a DMSO solution of PAT. Preconcentration of copper on polymer matrix was carried out at -0.7 V. The effects of preconcentration time and pH and Cu(II) concentration of the preconcentration solution on the stripping peak current of copper were studied.
Atıf Kaynağı Copper Technical Reference Library
Bir Parçası Olduğu Gazi University Journal of Science, 1901-01, Vol.24 (1), p.11-16
Purdue University Libraries
Purdue Üniversitesi Kütüphaneleri yönlendiriliyorsunuz...

Lütfen bekleyiniz.