Electrochemical determination of ceftriaxone using polyurethane-modified electrode containing caffeic acid and chitosan | Kütüphane.osmanlica.com

Electrochemical determination of ceftriaxone using polyurethane-modified electrode containing caffeic acid and chitosan

İsim Electrochemical determination of ceftriaxone using polyurethane-modified electrode containing caffeic acid and chitosan
Yazar Hassinea, Chedia Ben Ali, Güngör, Ö., Burc, M., Özcan, İ., Köytepe, S., Duran, S. T.
Basım Tarihi: 2022-04-13
Basım Yeri - Taylor & Francis
Konu Ceftriaxone, Polyurethane membrane, Electrode modification, Sensor, Voltammetry
Tür Süreli Yayın
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 2574-0881
Kayıt Numarası d0b982d5-f7c6-4eea-a9ff-75b6d95191db
Tarih 2022-04-13
Örnek Metin The aim of this work was to develop an electrochemical sensor based on caffeic acid and chitosan-containing polyurethane (CAC-PU) films modified platinum electrode for ceftriaxone (CFX) determination. For this aim, firstly the CAC-PU structures were synthesized from three different diisocyanates and these structures were characterized with spectroscopic, thermal and surface analysis techniques. Then, these CAC-PU structures were coated on bare Pt electrode surface for the preparation of CFX selective sensors. Throughout this study several analytical parameters, such as film thickness, electrolyte type, pH effect, and scan rate were investigated by using differential pulse voltammetry (DPV) method. Under the optimized conditions, the voltammetric test results showed best analytical performances for CFX detection with a linear range from 0.1 to 1.5 mM. Limit of detection (LOD) and correlation coefficient (R-2) were obtained 52 mu M and 0.9991 using CAC-PU modified electrode, respectively. Stability of the modified electrode was found to be 96.78% by using reproducibility experiments (n = 10). Applicable of the presented sensor was tested in two synthetic urine samples and recoveries values were obtained 98.7% and 110%, respectively. The prepared modified electrode exhibits high repeatability, fast response, and high sensitivity, which makes it suitable for the detection of CFX in urine samples.
DOI 10.1080/25740881.2021.2005092
Cilt 61
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Electrochemical determination of ceftriaxone using polyurethane-modified electrode containing caffeic acid and chitosan

Yazar Hassinea, Chedia Ben Ali, Güngör, Ö., Burc, M., Özcan, İ., Köytepe, S., Duran, S. T.
Basım Tarihi 2022-04-13
Basım Yeri - Taylor & Francis
Konu Ceftriaxone, Polyurethane membrane, Electrode modification, Sensor, Voltammetry
Tür Süreli Yayın
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 2574-0881
Kayıt Numarası d0b982d5-f7c6-4eea-a9ff-75b6d95191db
Tarih 2022-04-13
Örnek Metin The aim of this work was to develop an electrochemical sensor based on caffeic acid and chitosan-containing polyurethane (CAC-PU) films modified platinum electrode for ceftriaxone (CFX) determination. For this aim, firstly the CAC-PU structures were synthesized from three different diisocyanates and these structures were characterized with spectroscopic, thermal and surface analysis techniques. Then, these CAC-PU structures were coated on bare Pt electrode surface for the preparation of CFX selective sensors. Throughout this study several analytical parameters, such as film thickness, electrolyte type, pH effect, and scan rate were investigated by using differential pulse voltammetry (DPV) method. Under the optimized conditions, the voltammetric test results showed best analytical performances for CFX detection with a linear range from 0.1 to 1.5 mM. Limit of detection (LOD) and correlation coefficient (R-2) were obtained 52 mu M and 0.9991 using CAC-PU modified electrode, respectively. Stability of the modified electrode was found to be 96.78% by using reproducibility experiments (n = 10). Applicable of the presented sensor was tested in two synthetic urine samples and recoveries values were obtained 98.7% and 110%, respectively. The prepared modified electrode exhibits high repeatability, fast response, and high sensitivity, which makes it suitable for the detection of CFX in urine samples.
DOI 10.1080/25740881.2021.2005092
Cilt 61
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.