Effects of turbulence intensity and length scale on the flame location of premixed turbulent combustion in a diffuser combustor | Kütüphane.osmanlica.com

Effects of turbulence intensity and length scale on the flame location of premixed turbulent combustion in a diffuser combustor

İsim Effects of turbulence intensity and length scale on the flame location of premixed turbulent combustion in a diffuser combustor
Yazar Nazzal, Ibrahim Thamer, Ertunç, Özgür
Basım Tarihi: 2017
Basım Yeri - J-STAGE
Konu Premixed flame, Flame location, Diffuser, Turbulence, Flow separation
Tür Süreli Yayın
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 1880-5566
Kayıt Numarası b315811e-9ff2-4c96-b316-cf38406d0db7
Lokasyon Mechanical Engineering
Tarih 2017
Notlar TÜBİTAK ; Tikrit University ; Ozyegin University
Örnek Metin This study focused on the dependency of the flame location of a premixed propane-air flame on turbulence intensity and length scale. The flame location was investigated using a diffuser-type combustor to show the response of the flame location to varying turbulence intensities and length scales without changing the mixture velocity, i.e., the thermal power. Combustion simulations were conducted using a coherent flame model within the framework of Reynolds-averaged Navier-Stokes equations under unsteady state conditions. The flame generally moved toward the combustor inlet with increases in turbulence intensity and length scale. The combustion and inlet turbulence caused a flow separation mainly downstream of the flame front. Consequently, the secondary flow structures influenced the flame topology and location.
DOI 10.1299/jtst.2017jtst0029
Cilt 12
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Effects of turbulence intensity and length scale on the flame location of premixed turbulent combustion in a diffuser combustor

Yazar Nazzal, Ibrahim Thamer, Ertunç, Özgür
Basım Tarihi 2017
Basım Yeri - J-STAGE
Konu Premixed flame, Flame location, Diffuser, Turbulence, Flow separation
Tür Süreli Yayın
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 1880-5566
Kayıt Numarası b315811e-9ff2-4c96-b316-cf38406d0db7
Lokasyon Mechanical Engineering
Tarih 2017
Notlar TÜBİTAK ; Tikrit University ; Ozyegin University
Örnek Metin This study focused on the dependency of the flame location of a premixed propane-air flame on turbulence intensity and length scale. The flame location was investigated using a diffuser-type combustor to show the response of the flame location to varying turbulence intensities and length scales without changing the mixture velocity, i.e., the thermal power. Combustion simulations were conducted using a coherent flame model within the framework of Reynolds-averaged Navier-Stokes equations under unsteady state conditions. The flame generally moved toward the combustor inlet with increases in turbulence intensity and length scale. The combustion and inlet turbulence caused a flow separation mainly downstream of the flame front. Consequently, the secondary flow structures influenced the flame topology and location.
DOI 10.1299/jtst.2017jtst0029
Cilt 12
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.