Örnek Metin Insulation panels composed of perlite, pumice, and cement were fabricated. Perlite and pumice were used to achieve high thermal resistance, and low density. Experimentation was conducted for determining R-values of perlite-pumice-cement (PPC) panels at different moisture content values. Dry and moist sample panels were tested with and without soil and moss at the top where the one with the soil and plant coupling represents a green roof. Reverse heat leak method was used in determination of the R-values of the samples. Verification of theory was achieved via experimentation with an acceptable error range. Thermal diffusivity values of the developed samples were measured using flash method.
DOI 10.1016/j.jobe.2016.02.015
Cilt 6
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Analysis of perlite and pumice based building insulation materials

Yazar Çelik, S., Family, Roxana, Mengüç, Mustafa Pınar
Basım Tarihi 2016-06
Basım Yeri - Elsevier
Konu Insulation, Perlite, Pumice, Moisture, R-value, Thermal diffusivity
Tür Süreli Yayın
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 2-s2.0-84961182508
Kayıt Numarası 54ab1f1e-0bcb-4748-a433-d40131d7e937
Lokasyon Mechanical Engineering
Tarih 2016-06
Notlar Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Örnek Metin Insulation panels composed of perlite, pumice, and cement were fabricated. Perlite and pumice were used to achieve high thermal resistance, and low density. Experimentation was conducted for determining R-values of perlite-pumice-cement (PPC) panels at different moisture content values. Dry and moist sample panels were tested with and without soil and moss at the top where the one with the soil and plant coupling represents a green roof. Reverse heat leak method was used in determination of the R-values of the samples. Verification of theory was achieved via experimentation with an acceptable error range. Thermal diffusivity values of the developed samples were measured using flash method.
DOI 10.1016/j.jobe.2016.02.015
Cilt 6
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.