Voltammetric determination of resveratrol using poly(l-phenylalanine)-modified gold electrode | Kütüphane.osmanlica.com

Voltammetric determination of resveratrol using poly(l-phenylalanine)-modified gold electrode

İsim Voltammetric determination of resveratrol using poly(l-phenylalanine)-modified gold electrode
Yazar Gungor, O., Hassıne, Chedıa Ben Alı, Burc, M., Duran, S. T.
Basım Tarihi: 2020
Basım Yeri - Society of Chemists and Technologists of Macedonia
Konu L-phenylalanine, Resveratrol, Electropolymerization, Square wave voltammetry
Tür Süreli Yayın
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 1857-5552
Kayıt Numarası 3d032ad1-97bf-4813-b9a4-1863d982a8df
Tarih 2020
Örnek Metin In this study, we investigated the electrochemical modification of a gold electrode using poly(L-phenylalanine) and its applicability for the quantification of resveratrol (RESV). The gold electrode was modified with L-phenylalanine employing cyclic voltammetry (CV) in aqueous solution. The detection of RESV with the modified electrode was investigated by square wave voltammetry (SWV) in a phosphate buffer solution (PBS) (pH = 1.2). The analytical calibration curve for RESV showed a linear response with concentration in the oxidation peak current range from 50 to 1000 mu M, with a limit of detection (LOD) of 35.16 mu M and limit of quantitation (LOQ) of 105.5 mu M. The application of the prepared electrochemical sensor was carried out with a standard addition method in red wine samples.
DOI 10.20450/mjcce.2020.2073
Cilt 39
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Voltammetric determination of resveratrol using poly(l-phenylalanine)-modified gold electrode

Yazar Gungor, O., Hassıne, Chedıa Ben Alı, Burc, M., Duran, S. T.
Basım Tarihi 2020
Basım Yeri - Society of Chemists and Technologists of Macedonia
Konu L-phenylalanine, Resveratrol, Electropolymerization, Square wave voltammetry
Tür Süreli Yayın
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 1857-5552
Kayıt Numarası 3d032ad1-97bf-4813-b9a4-1863d982a8df
Tarih 2020
Örnek Metin In this study, we investigated the electrochemical modification of a gold electrode using poly(L-phenylalanine) and its applicability for the quantification of resveratrol (RESV). The gold electrode was modified with L-phenylalanine employing cyclic voltammetry (CV) in aqueous solution. The detection of RESV with the modified electrode was investigated by square wave voltammetry (SWV) in a phosphate buffer solution (PBS) (pH = 1.2). The analytical calibration curve for RESV showed a linear response with concentration in the oxidation peak current range from 50 to 1000 mu M, with a limit of detection (LOD) of 35.16 mu M and limit of quantitation (LOQ) of 105.5 mu M. The application of the prepared electrochemical sensor was carried out with a standard addition method in red wine samples.
DOI 10.20450/mjcce.2020.2073
Cilt 39
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.