Comparison of DC-link capacitor types under various grid conditions | Kütüphane.osmanlica.com

Comparison of DC-link capacitor types under various grid conditions

İsim Comparison of DC-link capacitor types under various grid conditions
Yazar Bilgin, M. S., Poyrazoğlu, Göktürk, Aktem, M., Er, E.
Basım Tarihi: 2019-04
Basım Yeri - IEEE
Konu Capacitor type, Converter, Converter;, Grid stabilization, THD, Unbalance
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 2-s2.0-85074162167
Kayıt Numarası 54f56e03-6864-4517-a7c1-9205b3bb186e
Lokasyon Electrical & Electronics Engineering
Tarih 2019-04
Örnek Metin A DC/AC converter can face negative conditions of power systems such as instability. One of the most crucial necessities of the grid is voltage stability. There are some effects of voltage unbalance for grid-tied DC/AC converters. Grid voltage unbalance causes higher THD values on grid currents than normal grid conditions. THD value of grid current is limited by the IEEE 519-2014 standard. Unstable grid conditions show different results because of the value and type of DC-Link capacitors. In this paper, two types of capacitors are compared with different grid voltage conditions and power factor values for grid-tied 10kVA DC/AC converter. Simulation results are shown and interpreted.
DOI 10.1109/CPE.2019.8862432
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Comparison of DC-link capacitor types under various grid conditions

Yazar Bilgin, M. S., Poyrazoğlu, Göktürk, Aktem, M., Er, E.
Basım Tarihi 2019-04
Basım Yeri - IEEE
Konu Capacitor type, Converter, Converter;, Grid stabilization, THD, Unbalance
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 2-s2.0-85074162167
Kayıt Numarası 54f56e03-6864-4517-a7c1-9205b3bb186e
Lokasyon Electrical & Electronics Engineering
Tarih 2019-04
Örnek Metin A DC/AC converter can face negative conditions of power systems such as instability. One of the most crucial necessities of the grid is voltage stability. There are some effects of voltage unbalance for grid-tied DC/AC converters. Grid voltage unbalance causes higher THD values on grid currents than normal grid conditions. THD value of grid current is limited by the IEEE 519-2014 standard. Unstable grid conditions show different results because of the value and type of DC-Link capacitors. In this paper, two types of capacitors are compared with different grid voltage conditions and power factor values for grid-tied 10kVA DC/AC converter. Simulation results are shown and interpreted.
DOI 10.1109/CPE.2019.8862432
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.