Signal to noise ratio optimization for a CMUT based medical ultrasound imaging system | Kütüphane.osmanlica.com

Signal to noise ratio optimization for a CMUT based medical ultrasound imaging system

İsim Signal to noise ratio optimization for a CMUT based medical ultrasound imaging system
Yazar Zangabad, R. P., Bozkurt, A., Yaralıoğlu, Göksen Göksenin
Basım Tarihi: 2015
Basım Yeri - IEEE
Konu Biomedical transducers, Biomedical ultrasonics, Capacitive transducers, Ultrasonic transducers
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 978-1-4799-8182-3
Kayıt Numarası a801e879-54e4-4bfd-8adf-e016f60da760
Lokasyon Electrical & Electronics Engineering
Tarih 2015
Notlar Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Örnek Metin CMUTs offers key performance benefits compared to their piezoelectric counterparts. However, CMUTs are not widely adopted in commercial ultrasound imaging systems due to low signal to noise ratio (SNR) in the obtained images. Tunable parameters of the CMUT include the membrane material, radius, thickness, gap height, electrode size, and bias voltage. The aim of this work is to optimize these parameters to provide a solution for low SNR problem of CMUTs. In medical imaging, the device will be used in pulse echo mode for which both good receive sensitivity and high output pressure is required. Optimizing these performance metrics will end up in conflicting design parameters, such as a high gap for large pressure output whereas a small gap for better receive sensitivity. In this work, we develop a methodology for the investigation of the round-trip behavior of the transducer and try to co-optimize transmit and receive characteristics of the device to maximize the SNR of the received signal by tuning the bias voltage.
DOI 10.1109/ULTSYM.2015.0470
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Signal to noise ratio optimization for a CMUT based medical ultrasound imaging system

Yazar Zangabad, R. P., Bozkurt, A., Yaralıoğlu, Göksen Göksenin
Basım Tarihi 2015
Basım Yeri - IEEE
Konu Biomedical transducers, Biomedical ultrasonics, Capacitive transducers, Ultrasonic transducers
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 978-1-4799-8182-3
Kayıt Numarası a801e879-54e4-4bfd-8adf-e016f60da760
Lokasyon Electrical & Electronics Engineering
Tarih 2015
Notlar Due to copyright restrictions, the access to the full text of this article is only available via subscription.
Örnek Metin CMUTs offers key performance benefits compared to their piezoelectric counterparts. However, CMUTs are not widely adopted in commercial ultrasound imaging systems due to low signal to noise ratio (SNR) in the obtained images. Tunable parameters of the CMUT include the membrane material, radius, thickness, gap height, electrode size, and bias voltage. The aim of this work is to optimize these parameters to provide a solution for low SNR problem of CMUTs. In medical imaging, the device will be used in pulse echo mode for which both good receive sensitivity and high output pressure is required. Optimizing these performance metrics will end up in conflicting design parameters, such as a high gap for large pressure output whereas a small gap for better receive sensitivity. In this work, we develop a methodology for the investigation of the round-trip behavior of the transducer and try to co-optimize transmit and receive characteristics of the device to maximize the SNR of the received signal by tuning the bias voltage.
DOI 10.1109/ULTSYM.2015.0470