Mutual radiation impedance of circular CMUTs on a cylinder | Kütüphane.osmanlica.com

Mutual radiation impedance of circular CMUTs on a cylinder

İsim Mutual radiation impedance of circular CMUTs on a cylinder
Yazar Zangabad, R. P., Bozkurt, A., Yaralıoğlu, Göksen Göksenin, Bosch, J. G., Soest, G. van, Steen, A. F. W. van der
Basım Tarihi: 2016
Basım Yeri - IEEE
Konu SL-IVUS, Mutual coupling
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane: Özyeğin Üniversitesi
Demirbaş Numarası 1948-5727
Kayıt Numarası d0bd7aea-9c6a-4808-a541-e1225b364470
Lokasyon Electrical & Electronics Engineering
Tarih 2016
Notlar ENIAC JU
Örnek Metin In ultrasound imaging, cross coupling of transducer elements through the medium has significant effect on the frequency response, thus affecting the quality of the ultrasound image. In Side-Looking Intravascular Ultrasound (SL-IVUS) imaging a radial image of the vessel wall is formed using a transducer array in a cylindrical configuration. Recent advances in Capacitive Micromachined Ultrasound Transducer (CMUT) fabrication and integration techniques led to realization of CMUT arrays that can be wrapped into a cylinder shape and mounted on a catheter tip. In this paper, we present the calculation of radiation impedance of un-collapse CMUT arrays on a planar rigid baffle and on a cylinder using Finite Element Method (FEM) simulation. We link the crosstalk between planar CMUT elements with dips in frequency spectrum from experimental data and conclude that decreasing the cylinder radius causes downshift of the dips in frequency response. In the case of our device, these changes are too small to have detrimental effects on the array bandwidth.
DOI 10.1109/ULTSYM.2016.7728767
Kaynağa git Özyeğin Üniversitesi Özyeğin Üniversitesi
Özyeğin Üniversitesi Özyeğin Üniversitesi
Kaynağa git

Mutual radiation impedance of circular CMUTs on a cylinder

Yazar Zangabad, R. P., Bozkurt, A., Yaralıoğlu, Göksen Göksenin, Bosch, J. G., Soest, G. van, Steen, A. F. W. van der
Basım Tarihi 2016
Basım Yeri - IEEE
Konu SL-IVUS, Mutual coupling
Tür Belge
Dil İngilizce
Dijital Evet
Yazma Hayır
Kütüphane Özyeğin Üniversitesi
Demirbaş Numarası 1948-5727
Kayıt Numarası d0bd7aea-9c6a-4808-a541-e1225b364470
Lokasyon Electrical & Electronics Engineering
Tarih 2016
Notlar ENIAC JU
Örnek Metin In ultrasound imaging, cross coupling of transducer elements through the medium has significant effect on the frequency response, thus affecting the quality of the ultrasound image. In Side-Looking Intravascular Ultrasound (SL-IVUS) imaging a radial image of the vessel wall is formed using a transducer array in a cylindrical configuration. Recent advances in Capacitive Micromachined Ultrasound Transducer (CMUT) fabrication and integration techniques led to realization of CMUT arrays that can be wrapped into a cylinder shape and mounted on a catheter tip. In this paper, we present the calculation of radiation impedance of un-collapse CMUT arrays on a planar rigid baffle and on a cylinder using Finite Element Method (FEM) simulation. We link the crosstalk between planar CMUT elements with dips in frequency spectrum from experimental data and conclude that decreasing the cylinder radius causes downshift of the dips in frequency response. In the case of our device, these changes are too small to have detrimental effects on the array bandwidth.
DOI 10.1109/ULTSYM.2016.7728767
Özyeğin Üniversitesi
Özyeğin Üniversitesi yönlendiriliyorsunuz...

Lütfen bekleyiniz.